Part Number Hot Search : 
5N200 STX112 2SA1963 KRM02 F38347 1SS133 OX9741 HC1228W
Product Description
Full Text Search
 

To Download PS-120 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 120W Single Output Power Supply or Battery Charger
Features :
PS-120
series
AC input range selected by switch Built-in passive PFC function compliance to EN61000-3-2 With AC ON-OFF switch 3 poles AC inlet with fuse holder Protections: Short circuit / Overload / Over voltage / Over temperature Charger type can be selected (Optional) Charger for lead-acid batteries 2 color LED loading indicator Open frame models available (Without safety approval) Low cost, High reliability 2 years warranty
TUV Rheinland Product Safety
geprUfre Sicherheit
S:Power Supply A:Voltage detector B:Current detector P:With PFC N:None PFC
PA
120 P
13 C :O.D.M. number P:Open P.C.B. C:With case 13:13.8V 27:27.6V 54:55.2V
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. PS-120-13P/C 13.8V 7.2A 0 ~ 7.2A 99.36W 12 ~ 15V 3.0% 8.5% 1.0% 1.0% 6.0% 1000ms, 50ms at full load 16ms at full load 88 ~ 132VAC / 176 ~ 264VAC selected by switch 47~63Hz >0.65 (with PFC series) 77%/70% 3A/115VAC 1.5A/230VAC COLD START 25A/115VAC <1.5mA / 240VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 15 ~ 17V 30 ~ 35V 60 ~ 66V Protection type : Hiccup mode, recovers automatically after fault condition is removed RTH2 70 10 detect on RTH2 thermistor Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 81%/76% 50A/230VAC 82%/78% PS-120-27P/C 27.6V 4.3A 0 ~ 4.3A 118.68W 200mVp-p 24 ~ 30V 1.0% 8.0% 1.0% 1.0% 5.0% PS-120-54P/C 54V 2.2A 0 ~ 2.2A 118.8W 250mVp-p 48 ~ 60V 1.0% 7.5% 1.0% 1.0% 5.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 45 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 4)
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 249.5K hrs min. MIL-HDBK-217F (25 ) PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H) 1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC)
OTHERS
NOTE
MTBF DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. With PFC I/P range: 95~132VAC/190~264VAC. 6. For open P.C.B. WITH 17.8CFM min. Forced air.
120W Single Output Power Supply or Battery Charger
Mechanical Specification
PS-120
Case No. PS-120A
series
Unit:mm
1 3
2
CASE: Output cable length=183cm 5cm
Pin No. 1 2,3 Assignment DC OUTPUT +V DC OUTPUT -V
PCB: AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
4180 144 134 5
DC Output Connector (CN3) : JST B4P-VH or equivalent
1234
Pin No. 1,2 3,4
Assignment -V +V
Mating Housing JST VHR or equivalent
Terminal JST SVH-21T-P1.1 or equivalent
5
CN3 +V
90
80
12VDC FAN Output Connector (CN4) : JST B2B-XH or equivalent
Pin No. 1 2 Assignment +V -V Mating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent
ADJ.
CN4 F4 A/250V 12 +CN5 123 CN1 SHORT FOR 115V OPEN FOR 230V
LED
115/230V selected by switch Connector (CN5) : JST B2P-VH or equivalent
Switch 115V 230V Assignment Short Open Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
33
Derating Curve
2 max.
Static Characteristics (27V)
Ta=25
100
30
-V
49
115
80
OUTPUT VOLTAGE (V)
Open frame series 17.8CFM air cooling (L=15cm face HS) Other series
29 28 27 26 25 24
300 250 200 150 100 50
60
40
20
-10
0
10
20
30
40
50
60
(HORIZONTAL)
80 160
85 170
90 180
95 190
100 200
105 210
110 220
115 230
120 240
125 250
130 260
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:PA,PB-120-SPEC 2008-05-06
OUTPUT RIPPLE (mVp-p)
FUSE
3. 8
350
LOAD (%)


▲Up To Search▲   

 
Price & Availability of PS-120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X